title: How to Perform a Radiation Survey on a Loaded Gamma Projector
description: Learn how to perform a radiation survey on a loaded gamma projector before use. This step-by-step guide covers safety checks and measurement thresholds.
image: https://www.qsa-global.com/hubfs/2024/Blog/gamma-ray%20source%20projector%20survey.webp
---

![Featured Image](https://www.qsa-global.com/hubfs/2024/Blog/gamma-ray%20source%20projector%20survey.webp)

<https://www.facebook.com/sharer/sharer.php?u=https://www.qsa-global.com/learn/perform-radiation-survey> <https://twitter.com/intent/tweet?text=&url=https://www.qsa-global.com/learn/perform-radiation-survey> <https://www.linkedin.com/sharing/share-offsite/?url=https://www.qsa-global.com/learn/perform-radiation-survey>

# How to Perform a Radiation Survey on a Loaded Gamma Projector

 By Theo Ewing | Jan 13, 2025 | [ Gamma Radiography, ](https://www.qsa-global.com/learn/tag/gamma-radiography) [ 880 Series, ](https://www.qsa-global.com/learn/tag/880-series) [ Inspection & Maintenance ](https://www.qsa-global.com/learn/tag/inspection-maintenance)

If you’re handling a gamma projector, be it coming in through your transport or coming off the rig onto the job site, the first thing you should do is perform a radiation survey. It doesn’t matter how it looks from the outside. The only way to confirm it's safe and ready is to check the dose rates yourself.

## Why the Initial Survey Matters

Before any radiographic work begins, a survey confirms the unit’s shielding is intact and the source is secure. Survey results help detect potential shielding issues or unintended source exposure due to internal faults, damage during transport, or source misalignment. Radiation levels must be within acceptable limits to protect you, your team, and anyone else in the area. This step is also required for regulatory compliance. Failure to conduct the survey properly can lead to operational delays, citations, or worse.

## Step-by-Step Survey Procedure

1. Use a calibrated survey meter. Make sure you're using an appropriate survey meter for the isotope type and energy level. In this video, we’re using the Tracerco T-402 survey meter.
2. Verify radiation levels are below 200 mR/hr on contact at all surfaces, including: 
     1. Front side (outlet port)
     2. Rear side (lock mechanism)
     3. Around the full circumference
     4. Bottom surface (tip the unit on its side to access)
3. Stand one meter from the projector and confirm the reading is below 10 mR/hr. This verifies the dose rate at 1 meter is within regulatory limits for safe handling and transport, as outlined in U.S. NRC and IAEA transport safety standards.

## What to Do if the Readings Are Off

If any of your measurements exceed the limits, stop work immediately[ [1] ](https://www.qsa-global.com/learn/perform-radiation-survey#NRC)[[2]](https://www.qsa-global.com/learn/perform-radiation-survey#IAEA). Don’t assume it's safe. Notify your Radiation Safety Officer or supervisor and have the projector evaluated before it’s used, and follow your facility’s safety protocols.

## Why We Emphasize Survey Techniques

Our commitment to safety extends beyond providing high-quality equipment. We want to ensure that every technician working with QSA Global products has the knowledge and skills to operate safely. Proper survey techniques are fundamental to protecting yourself and others while maximizing productivity with our radiography systems.

## Sources

1. S. Nuclear Regulatory Commission (NRC). *10 CFR Part 34 – [Licenses for Industrial Radiography and Radiation Safety Requirements for Industrial Radiographic Operations](https://www.nrc.gov/reading-rm/doc-collections/cfr/part034/)*.
2. International Atomic Energy Agency (IAEA). *[Regulations for the Safe Transport of Radioactive Material: 2018 Edition, SSR-6 Rev. 1](https://www.iaea.org/publications/12246/regulations-for-the-safe-transport-of-radioactive-material-2018-edition)*

---

***Note:** This guide focuses on initial survey procedures only. Additional safety protocols, emergency procedures, and specific regulatory requirements may apply based on jurisdiction and facility requirements. Always consult applicable safety manuals and regulatory guidelines for complete requirements.*

Share: <https://www.facebook.com/sharer/sharer.php?u=https://www.qsa-global.com/learn/perform-radiation-survey> <https://twitter.com/intent/tweet?text=&url=https://www.qsa-global.com/learn/perform-radiation-survey> <https://www.linkedin.com/sharing/share-offsite/?url=https://www.qsa-global.com/learn/perform-radiation-survey>

## Related Posts

- [![Related Post Image](https://www.qsa-global.com/hubfs/Blog%20Photos.png)](https://www.qsa-global.com/learn/the-importance-of-maintaining-your-co-60-sources)
  
  ### [The Importance of Maintaining Your Co-60 Sources](https://www.qsa-global.com/learn/the-importance-of-maintaining-your-co-60-sources)
  
  Cobalt‑60 (Co‑60) exposure devices used in industrial radiography are engineered for long‑term operation and reliability. While many devices and ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/the-importance-of-maintaining-your-co-60-sources)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/%232%20Daily%20Inspection%20880%20Series.jpg)](https://www.qsa-global.com/learn/daily-inspection)
  
  ### [Daily Gamma Radiography Equipment Inspection: A Step-by-Step Guide](https://www.qsa-global.com/learn/daily-inspection)
  
  Daily equipment inspection is a crucial safety requirement before performing gamma radiography. Both Agreement State and NRC regulations mandate ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/daily-inspection)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Operating%20Instructions/How%20to%20change1075%20SCARPro%20Projection%20to%20Contact.webp)](https://www.qsa-global.com/learn/1075-projection-to-scar)
  
  ### [How to Convert the 1075 SCARPro from Projection to SCAR Configuration](https://www.qsa-global.com/learn/1075-projection-to-scar)
  
  In this step-by-step walkthrough, Theo Ewing from our Baton Rouge Service Center demonstrates the process for switching the 1075 SCAR*Pro* ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/1075-projection-to-scar)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Perform%20a%20Misconnect%20Test.webp)](https://www.qsa-global.com/learn/how-to-perform-a-misconnect-test-safety-procedure-for-rsos)
  
  ### [How to Perform a Misconnect Test: Safety Procedure for RSOs](https://www.qsa-global.com/learn/how-to-perform-a-misconnect-test-safety-procedure-for-rsos)
  
  The 30-second misconnect test is a mandatory safety procedure, required by radiation safety regulations, that verifies if your radiography ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/how-to-perform-a-misconnect-test-safety-procedure-for-rsos)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Perform%20a%20Leak%20Test.webp)](https://www.qsa-global.com/learn/how-to-leak-test)
  
  ### [How to Perform a Leak Test on Your Gamma-Ray Source Projector](https://www.qsa-global.com/learn/how-to-leak-test)
  
  Performing a leak test on your gamma radiography projector is a required part of maintaining compliance with NRC and Agreement State regulations. ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/how-to-leak-test)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/howto%20calculate%20exposure%20time.webp)](https://www.qsa-global.com/learn/calculating-exposure-time)
  
  ### [Calculating Exposure Time in Gamma Radiography: A Comprehensive Guide](https://www.qsa-global.com/learn/calculating-exposure-time)
  
  Learn how to calculate exposure time in gamma radiography with this comprehensive guide. Discover the factors that affect exposure time and the ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/calculating-exposure-time)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/%236-How%20to%20Drive%20Cables%20-%20frame%20at%200m22s.jpg)](https://www.qsa-global.com/learn/how-to-inspect-drive-cables)
  
  ### [How to Inspect Drive Cables: A Field-Ready Guide for NDT Techs](https://www.qsa-global.com/learn/how-to-inspect-drive-cables)
  
  Drive cables take a beating. Between setup, teardown, transport, and exposure to rough site conditions, they're one of the first components to ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/how-to-inspect-drive-cables)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Perform%20a%20Guide%20Tube%20Inspection.webp)](https://www.qsa-global.com/learn/inspect-guide-tubes)
  
  ### [How to Inspect Guide Tubes: A Field-Ready Guide for NDT Techs](https://www.qsa-global.com/learn/inspect-guide-tubes)
  
  Routine inspection of guide tubes and collimators helps prevent source retrievals and ensures equipment remains safe and functional. The steps ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/inspect-guide-tubes)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Inspect%20880%20Series%20Components.webp)](https://www.qsa-global.com/learn/component-inspection)
  
  ### [How to Inspect Projector Components for Safety and Compliance](https://www.qsa-global.com/learn/component-inspection)
  
  A crucial part of your role as a radiographer is to ensure your equipment functions safely and remains in compliance with certification ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/component-inspection)

<https://www.qsa-global.com/learn/perform-radiation-survey#> <https://www.qsa-global.com/learn/perform-radiation-survey#>

![](https://px.ads.linkedin.com/collect/?pid=5603804&fmt=gif)

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Theo Ewing",
    "url" : "https://www.qsa-global.com/learn/author/theo-ewing"
  },
  "dateModified" : "2026-05-07T17:59:07.338Z",
  "datePublished" : "2025-01-13T15:45:00.000Z",
  "headline" : "How to Perform a Radiation Survey on a Loaded Gamma Projector",
  "image" : [ "https://www.qsa-global.com/hubfs/2024/Blog/gamma-ray%20source%20projector%20survey.webp" ],
  "mainEntityOfPage" : {
    "@id" : "https://www.qsa-global.com/learn/perform-radiation-survey",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://www.qsa-global.com/hubfs/QSA_Logo_Web.png"
    },
    "name" : "QSA Global, Inc."
  }
}
```