<https://www.facebook.com/sharer/sharer.php?u=https://www.qsa-global.com/learn/inspect-guide-tubes> <https://twitter.com/intent/tweet?text=&url=https://www.qsa-global.com/learn/inspect-guide-tubes> <https://www.linkedin.com/sharing/share-offsite/?url=https://www.qsa-global.com/learn/inspect-guide-tubes>

# How to Inspect Guide Tubes: A Field-Ready Guide for NDT Techs

 By Theo Ewing | Nov 11, 2024 | [ Gamma Radiography, ](https://www.qsa-global.com/learn/tag/gamma-radiography) [ 880 Series, ](https://www.qsa-global.com/learn/tag/880-series) [ Inspection & Maintenance ](https://www.qsa-global.com/learn/tag/inspection-maintenance)

Routine inspection of guide tubes and collimators helps prevent source retrievals and ensures equipment remains safe and functional. The steps below outline what to check and when to remove a guide tube from service.

## Types of Guide Tubes

QSA Global provides two guide tube options designed for different environmental conditions. The inspection process is the same for both.

**Standard Guide Tubes**

- Feature a yellow vinyl coating
- Intended for use in standard operating environments

**Extreme Condition Guide Tubes: **

- Feature a flexible black coating
- Designed for extreme temperatures ranging from −60°C to 135°C (−76°F to 275°F)

Knowing which type you're using helps you understand how the material should behave under normal handling during inspection.

## Daily Guide Tube Inspection Steps

### Visual Inspection

- Lay the guide tube out straight.
- Look for thermal damage, cuts, abrasions, or deformation.
- Focus on areas near the crimp connectors. Damage here may cause the connector to fail under load.

### Flex Test

- Gently bend the guide tube along its length.
- If it flexes too easily or unevenly, the internal metal conduit may be separated.
- If there's any doubt, inspect it with a borescope or return it for internal evaluation.

### Repair of Minor Cuts

If you see cuts in the middle of the tube that don’t affect the crimp area, wrap them with yellow vinyl electrical tape. This prevents mud, water, and debris from entering the space between the outer jacket and the internal conduit.

### Pro Tips for Extended Equipment Life

- Coil and store guide tubes without kinks
- Keep vinyl tape and a thread chaser on hand
- Make inspection part of your daily routine and train junior technicians to follow the same process

### When to Remove from Service

Remove your guide tubes from service if you see:

- Cuts or abrasions near the crimp connectors
- Excessive flexibility from suspected internal separation
- Rounded, worn, or smoothed source tip
- Indentations caused by collimator screws
- Threads that cannot be cleaned up using a thread chaser

## Connector Integrity Inspection

- Ensure bayonets rotate freely and have clean, square edges.
- For guide tubes with 1"-18 fittings, check that the threads are intact.
- Use a 1"-18 thread chaser to clean up any minor damage.

## Source Tip Inspection

- The source tip should have a clear, square-edged point.
- If the tip is worn, smooth, or rounded, it should be replaced.
- Dents or grooves from screw-on collimators are a sign the tube should be taken out of service.

## Jumper Connector Test (Periodically)

To check for internal blockages:

- Connect a short piece of drive cable to a jumper connector (same diameter as a source assembly)
- Pass it through the guide tube
- If it moves freely, the internal path is clear
- If it snags, stop and investigate further before use

## Collimator Handling

- Always loosen the screw on a screw-on collimator before turning
- Turning it while the screw is tight can create a groove or dent in the source tip
- If you can feel an indentation, remove the guide tube from service

## Why These Inspections Are Important

Most source retrievals we encounter stem from damage that could have been caught in a 2-minute inspection. A careful look each day protects your team, your equipment, and your schedule.

If you’re unsure about the integrity of your guide tube, contact QSA Global. We’ll inspect, advise, and make sure you’re operating safely and efficiently.

---

***Note:*** *This guide focuses on basic guide tube inspection procedures only. Additional safety protocols, emergency procedures, and specific regulatory requirements may apply based on jurisdiction and facility requirements. Always consult your company's radiation safety procedures, applicable safety manuals, and current regulatory guidelines for complete requirements.*

Share: <https://www.facebook.com/sharer/sharer.php?u=https://www.qsa-global.com/learn/inspect-guide-tubes> <https://twitter.com/intent/tweet?text=&url=https://www.qsa-global.com/learn/inspect-guide-tubes> <https://www.linkedin.com/sharing/share-offsite/?url=https://www.qsa-global.com/learn/inspect-guide-tubes>

## Related Posts

- [![Related Post Image](https://www.qsa-global.com/hubfs/Blog%20Photos.png)](https://www.qsa-global.com/learn/the-importance-of-maintaining-your-co-60-sources)
  
  ### [The Importance of Maintaining Your Co-60 Sources](https://www.qsa-global.com/learn/the-importance-of-maintaining-your-co-60-sources)
  
  Cobalt‑60 (Co‑60) exposure devices used in industrial radiography are engineered for long‑term operation and reliability. While many devices and ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/the-importance-of-maintaining-your-co-60-sources)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/%232%20Daily%20Inspection%20880%20Series.jpg)](https://www.qsa-global.com/learn/daily-inspection)
  
  ### [Daily Gamma Radiography Equipment Inspection: A Step-by-Step Guide](https://www.qsa-global.com/learn/daily-inspection)
  
  Daily equipment inspection is a crucial safety requirement before performing gamma radiography. Both Agreement State and NRC regulations mandate ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/daily-inspection)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Operating%20Instructions/How%20to%20change1075%20SCARPro%20Projection%20to%20Contact.webp)](https://www.qsa-global.com/learn/1075-projection-to-scar)
  
  ### [How to Convert the 1075 SCARPro from Projection to SCAR Configuration](https://www.qsa-global.com/learn/1075-projection-to-scar)
  
  In this step-by-step walkthrough, Theo Ewing from our Baton Rouge Service Center demonstrates the process for switching the 1075 SCAR*Pro* ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/1075-projection-to-scar)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Perform%20a%20Misconnect%20Test.webp)](https://www.qsa-global.com/learn/how-to-perform-a-misconnect-test-safety-procedure-for-rsos)
  
  ### [How to Perform a Misconnect Test: Safety Procedure for RSOs](https://www.qsa-global.com/learn/how-to-perform-a-misconnect-test-safety-procedure-for-rsos)
  
  The 30-second misconnect test is a mandatory safety procedure, required by radiation safety regulations, that verifies if your radiography ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/how-to-perform-a-misconnect-test-safety-procedure-for-rsos)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Perform%20a%20Leak%20Test.webp)](https://www.qsa-global.com/learn/how-to-leak-test)
  
  ### [How to Perform a Leak Test on Your Gamma-Ray Source Projector](https://www.qsa-global.com/learn/how-to-leak-test)
  
  Performing a leak test on your gamma radiography projector is a required part of maintaining compliance with NRC and Agreement State regulations. ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/how-to-leak-test)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/howto%20calculate%20exposure%20time.webp)](https://www.qsa-global.com/learn/calculating-exposure-time)
  
  ### [Calculating Exposure Time in Gamma Radiography: A Comprehensive Guide](https://www.qsa-global.com/learn/calculating-exposure-time)
  
  Learn how to calculate exposure time in gamma radiography with this comprehensive guide. Discover the factors that affect exposure time and the ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/calculating-exposure-time)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/gamma-ray%20source%20projector%20survey.webp)](https://www.qsa-global.com/learn/perform-radiation-survey)
  
  ### [How to Perform a Radiation Survey on a Loaded Gamma Projector](https://www.qsa-global.com/learn/perform-radiation-survey)
  
  If you’re handling a gamma projector, be it coming in through your transport or coming off the rig onto the job site, the first thing you should ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/perform-radiation-survey)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/%236-How%20to%20Drive%20Cables%20-%20frame%20at%200m22s.jpg)](https://www.qsa-global.com/learn/how-to-inspect-drive-cables)
  
  ### [How to Inspect Drive Cables: A Field-Ready Guide for NDT Techs](https://www.qsa-global.com/learn/how-to-inspect-drive-cables)
  
  Drive cables take a beating. Between setup, teardown, transport, and exposure to rough site conditions, they're one of the first components to ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/how-to-inspect-drive-cables)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Inspect%20880%20Series%20Components.webp)](https://www.qsa-global.com/learn/component-inspection)
  
  ### [How to Inspect Projector Components for Safety and Compliance](https://www.qsa-global.com/learn/component-inspection)
  
  A crucial part of your role as a radiographer is to ensure your equipment functions safely and remains in compliance with certification ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/component-inspection)

<https://www.qsa-global.com/learn/inspect-guide-tubes#> <https://www.qsa-global.com/learn/inspect-guide-tubes#>

![](https://px.ads.linkedin.com/collect/?pid=5603804&fmt=gif)

```json
{
  "@context" : "https://schema.org",
  "@type" : "BlogPosting",
  "author" : {
    "@type" : "Person",
    "name" : "Theo Ewing",
    "url" : "https://www.qsa-global.com/learn/author/theo-ewing"
  },
  "dateModified" : "2026-05-07T18:01:38.533Z",
  "datePublished" : "2024-11-11T14:45:00.000Z",
  "headline" : "How to Inspect Guide Tubes: A Field-Ready Guide for NDT Techs",
  "image" : [ "https://www.qsa-global.com/hubfs/2024/Blog/Inspection%20Maintenance/How%20to%20Perform%20a%20Guide%20Tube%20Inspection.webp" ],
  "mainEntityOfPage" : {
    "@id" : "https://www.qsa-global.com/learn/inspect-guide-tubes",
    "@type" : "WebPage"
  },
  "publisher" : {
    "@type" : "Organization",
    "logo" : {
      "@type" : "ImageObject",
      "url" : "https://www.qsa-global.com/hubfs/QSA_Logo_Web.png"
    },
    "name" : "QSA Global, Inc."
  }
}
```