title: 1075 SCARPro Contact Fixture Kit | QSA Global
description: The Contact Fixture Kit mounts and secures the 1075 SCARPro gamma-ray source projector onto piping surfaces for immediate radiography testing.
---

![Bottom of 1075 SCARPro with contact fixture](https://5014511.fs1.hubspotusercontent-na1.net/hub/5014511/hubfs/2024/Accessories/1075%20SCARPro%20Contact%20Fixture.webp?width=1200&length=1200&name=1075%20SCARPro%20Contact%20Fixture.webp)

![1075 SCARPro with contact fixture](https://5014511.fs1.hubspotusercontent-na1.net/hub/5014511/hubfs/2024/Accessories/1075%20SCARPro%20with%20contact%20fixture.webp?width=1200&length=1200&name=1075%20SCARPro%20with%20contact%20fixture.webp)

![Bottom of 1075 SCARPro with contact fixture](https://5014511.fs1.hubspotusercontent-na1.net/hub/5014511/hubfs/2024/Accessories/Bottom%20of%201075%20SCARPro%20with%20contact%20fixture.webp?width=1200&length=1200&name=Bottom%20of%201075%20SCARPro%20with%20contact%20fixture.webp)

# 1075 SCAR*Pro* Contact Fixture.

## Mount the 1075 SCARPro directly to the pipe for secure Category I close-contact SCAR exposures.

Radiographers use the 1075 SCARPro Contact Fixture to perform Category I close-contact SCAR radiography by mounting the projector directly to the pipe surface. Contact shots are typically preferred on piping 3 in (7.6 cm) OD and above.

The Contact Fixture secures the 1075 SCARPro to any pipe diameter and supports both vertical and horizontal setup configurations, so radiographers can position the projector, lock the fixture in place, and complete close-contact exposures with repeatable placement.

## Support That Shows Up in the Field

- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Operating%20Instructions/How%20to%20change1075%20SCARPro%20Projection%20to%20Contact.webp)](https://www.qsa-global.com/learn/1075-projection-to-scar?hsLang=en)
  
  ### [How to Convert the 1075 SCARPro from Projection to SCAR Configuration](https://www.qsa-global.com/learn/1075-projection-to-scar?hsLang=en)
  
  In this step-by-step walkthrough, Theo Ewing from our Baton Rouge Service Center demonstrates the process for switching the 1075 SCAR*Pro* ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/1075-projection-to-scar?hsLang=en)
- [![Related Post Image](https://www.qsa-global.com/hubfs/2024/Blog/Close-Contact%20SCAR%20Radiation%20Dose%20at%2010ft.webp)](https://www.qsa-global.com/learn/close-contact-scar?hsLang=en)
  
  ### [How to Achieve 10 ft (3 m) Boundaries with Close-Contact SCAR](https://www.qsa-global.com/learn/close-contact-scar?hsLang=en)
  
  Radiographers use Close-Contact (Category I) SCAR to minimize source-to-film distance (SFD), reduce exclusion zones, and perform inspections near ...
  
  
  
  [Read Article](https://www.qsa-global.com/learn/close-contact-scar?hsLang=en)

<https://www.qsa-global.com/contact-fixture-kit#> <https://www.qsa-global.com/contact-fixture-kit#>

## Order the 1075 SCARPro Contact Fixture .

Talk with us about your workflow and we’ll make sure the 1075 SCAR*Pro* Contact Fixture is the right fit. We can do a live demo on-site or virtually to walk your team through setup and usage requirements.

[![Contact Us](https://no-cache.hubspot.com/cta/default/5014511/837601df-14b4-4927-adc2-281588a36137.png)](https://cta-redirect.hubspot.com/cta/redirect/5014511/837601df-14b4-4927-adc2-281588a36137)

## Request Support.

Our goal is to provide you with an outstanding ownership experience. We’re here to help with 1075 SCAR*Pro* Contact Fixture setup and use, assist with replacements, and ensure your equipment continues to meet safety and compliance standards.

[![Request Support](https://no-cache.hubspot.com/cta/default/5014511/a01ec454-7bc5-404d-b45c-e5ddd9051d6a.png)](https://cta-redirect.hubspot.com/cta/redirect/5014511/a01ec454-7bc5-404d-b45c-e5ddd9051d6a) 

![](https://px.ads.linkedin.com/collect/?pid=5603804&fmt=gif)